Fraud Blocker

Products

SoundEar 3-300 – high precision noise monitor

In Part Number: SE3-3
QTY

This high precision noise level monitor has visual alerts and noise level logging to help workplaces asses if ear protection is needed.

This high precision noise level monitor has visual alerts and noise level logging to help workplaces asses if ear protection is needed. It features a green, orange and red ear symbol on a black anti-shock background.

 

  • This high precision noise level monitor has a measuring range from 30 dB to 120 dB
  • It has the ability to turn off the visual warning signal at night so it doesn’t disturb patients sleeping in hospitals
  • Also features a built in log that saves LAeq measurements for up to 600 days
  • It allows you to view multiple units in real time in the SoundEar software by adding a wireless USB dongle
  • Easy transfer of log data into the SoundEar software via USB to give a complete overview of the noise environment
  • All measurements are saved in a CSV format and can be opened in Excel

Frequency Range: 20 Hz – 20 kHz

Measuring Level Range: 30 dB – 120 dB

Deviation: +/- 0.5 dB

Frequency Weighting: dB (A) & dB (C) filter

Time Weighting: Slow (1S) & (125mS)

Dynamic Range RMS: 90 dB and Peak detection

Light setting: Full configurability through SoundEar®
software including night setting.

2 x Outputs
(1 for dB A + 1 for dB C): Either 0-10V or 4-20mA outputs
2 x USB ports: Micro USB (Power &PC), USB OTG (Log, config.)

Display data: dB(A) Slow, Leq(A)15, Alarm settings, Temperature & Clock

Power supply: 5VDC (micro USB) / 24VDC (screw terminal)

Current consumption: max 2.5W.

Microphone: 20 Hz – 20 kHz

Internal memory:
16MB (128MBit) (5-90 days log time, depending on log settings)

Real Time Clock: Hi-precision type with battery backup (CR2032).

Mechanical properties: Cabinet: Shockproof acrylic.

Measurements:
Length: 265mm, Width: 205mm. Height: 46mm,
Weight: 1.5 kg.

Standards:
IEC61672-2-2002. Type 2, ANSI S1,4 Type 260601-1:
Medical electrical equipment – Part 1: General
requirements for basic safety and essential performance.
60601-1-2: Medical electrical equipment – Part 1-2:
General requirements for basic safety and
essential performance.